PHnw Building Directory

Elk Passive House

Building Use: Detached single-family residence

Project Type: New passive house building

Peaceful low-energy home.

rickey-exterior
State:Washington
Dwelling Units:1
PH Calculation Protocol(s):PHIUS+
PH Modeling Software(s):WUFI Passive
PH Certification(s):PHIUS
Year Of Construction:2013

Project Size

Floor Area:1,580.1 ft2iCFA146.8 m2iCFA

Performance

Annual heat demand:4.70 kBtu/yr•ft2iCFA14.8 kWh/yr•m2iCFA
Heat load:3.07 Btu/hr•ft2iCFA9.7 W/m2iCFA
Annual cooling demand:0.14 kBtu/yr•ft2iCFA0.4 kWh/yr•m2iCFA
Cooling load:1.13 Btu/hr•ft2iCFA3.6 W/m2iCFA
Primary energy demand:15.92 kBtu/yr•ft2iCFA50.2 kWh/yr•m2iCFA
Primary energy demand after on-site generation:15.92 kBtu/yr•ft2iCFA50.2 kWh/yr•m2iCFA
Airtightness:0.02 ft3/min•ft2

Envelope

Construction Type:wood
Floor Assembly:Crawl space, slab + 10" EPS
Wall Assembly:2 x 6 wall, 14" TJI wall with fiberglass insulation
Roof Assembly:Truss roof with 24" cellulose
Windows:Klearwall
Entry Doors:ThermaTru

Systems

Ventilation system:UltimateAir
Heating/Cooling system:Mitsubishi

Team

Passive House Consultant:Sam Rodell
Passive House Consultant Certification:PHIUS
Architect:Sam Rodell Architects
Contractor:Gavin Tenold, Pura Vida High Performance Builders

Comments

Additional Information:ACH50 0.58